From afa7517fc794c1d7fa43be5288591bf64c7cb8e7 Mon Sep 17 00:00:00 2001 From: Alexander von Gluck IV Date: Thu, 5 May 2011 18:35:43 +0000 Subject: [PATCH] small logic correction, string compare reversed for empty battery slot test git-svn-id: file:///srv/svn/repos/haiku/haiku/trunk@41321 a95241bf-73f2-0310-859d-f6bbb57e9c96 --- src/apps/powerstatus/ExtendedInfoWindow.cpp | 8 ++++---- 1 file changed, 4 insertions(+), 4 deletions(-) diff --git a/src/apps/powerstatus/ExtendedInfoWindow.cpp b/src/apps/powerstatus/ExtendedInfoWindow.cpp index 54ea20d93e..6335dd3e12 100644 --- a/src/apps/powerstatus/ExtendedInfoWindow.cpp +++ b/src/apps/powerstatus/ExtendedInfoWindow.cpp @@ -137,10 +137,10 @@ BatteryInfoView::_FillStringList() else if (fBatteryInfo.state & BATTERY_DISCHARGING) fontString->string = B_TRANSLATE("Battery discharging"); else if (fBatteryInfo.state & BATTERY_CRITICAL_STATE - && strcmp(fBatteryExtendedInfo.model_number, "") - && strcmp(fBatteryExtendedInfo.serial_number, "") - && strcmp(fBatteryExtendedInfo.type, "") - && strcmp(fBatteryExtendedInfo.oem_info, "")) + && !strcmp(fBatteryExtendedInfo.model_number, "") + && !strcmp(fBatteryExtendedInfo.serial_number, "") + && !strcmp(fBatteryExtendedInfo.type, "") + && !strcmp(fBatteryExtendedInfo.oem_info, "")) fontString->string = B_TRANSLATE("Empty battery slot"); else if (fBatteryInfo.state & BATTERY_CRITICAL_STATE) fontString->string = B_TRANSLATE("Damaged battery");